FEATURES |
● UL safety approval.
● 16A switching capabilities.
● 1 & 2 pole configurations.
● 5KV dielectric coil to contacts.
● Height is 15.7mm.
● Sealed & unsealed type available.
● Creepage distance 10mm.
● Sensitive coil 250mW. |
|
|
|
|
|
UL FILE NO:E171095/E188367
TUV FILE NO:
CE DECLARATION OF CONFORMITY
CQC FILE NO:
|
|
|
ORDERING INFORMATION |
Y02 |
H |
- |
1A |
- |
12 |
D |
S |
- |
T |
- |
F |
|
|
|
1 |
2 |
|
3 |
|
4 |
5 |
6 |
|
7 |
|
8 |
|
|
|
|
1 |
Model Number
Y02 |
2 |
Coil Sensitivity
Nil = Standard Type
H = High Sensitive Type |
3 |
Contact Arrangement
1A = 1 Form A (SPST-NO)
1C = 1 Form C (SPDT)
2A = 2 Form A (DPST-NO)
2C = 2 Form C (DPDT)
|
4 |
Coil Voltage
5-110V |
5 |
Coil Type
D:DC |
6 |
Enclosure
Nil = Standard Type
S = Sealed Type |
7 |
Terminal Type
Nil = One Foot
T = Two Feet (Remark: "T" is for 1 Pole only)
|
8 |
Type of Insulation
Nil = Class A
F = Class F |
|
|
COIL RATINGS (at 20℃) |
COIL
TYPE |
Coil Nominal
Voltage (V) |
Coil
Resistance
(Ω+-10%) |
Pick-Up
Voltage (V)
<= |
Drop-Out
Voltage (V)
>= |
Nominal
Current
(mA) |
DC Standard Coils |
5 |
62 |
3.5 |
0.5 |
80.6 |
6 |
90 |
4.2 |
0.6 |
66.7 |
9 |
200 |
6.3 |
0.9 |
45 |
12 |
360 |
8.4 |
1.2 |
33.3 |
24 |
1440 |
16.8 |
2.4 |
16.7 |
48 |
5520 |
33.6 |
4.8 |
8.7 |
|
|
* Max Continuous Voltage at 20℃:? 130% of Coil Nominal Voltage. |
CONTACT RATINGS |
●Contact Arrangement |
|
●Max. Switching Power |
|
|
●Max. Switching Voltage |
|
● Max. Switching Current |
|
|
●Contact Resistance |
|
●Resistive Load |
|
|
●Contact Material |
|
●Inductive Load |
|
●Pilot Duty Load |
|
●Rating Load |
|
●Tv Rating |
|
●Remark |
|
|
|
CHARACTERISTICS |
●Electrical Life |
100,000 |
●Mechanical Life |
10,000,000 |
●Initial Insulation Resistance |
Min. 1000MΩ 500VDC |
●Contact Resistance (Initial) |
≤100mΩ |
●Operate Time |
≤7ms(excluding bounce) typ 15ms max at nom voltage |
●Release Time |
≤3ms(excluding bounce) typ 5ms max at nom voltage |
●Initial Dielectric Strength |
50/60Hz 1000VAC 1min. (between open contacts)
50/60Hz 5000VAC 1min. (between contacts and coil)
50/60Hz 2500VAC 1min. (between contact sets)
|
● Vibration Resistance |
Malfunction: 10 to 55Hz at Double Amplitude of 1.5mm
Destructive: 10 to 55Hz at Double Amplitude of 1.5mm
|
●Shock Resistance |
Malfunction: 10G (11ms) / Destructive: 100G (6ms) |
●Ambient Temperature |
-40℃~+85℃ |
●Relative Humidity |
85% at 40℃ |
●Unit Weight |
Approx. 13g |
●Remark |
|
|
|